Fire Safety Compliance Inspections Perth
Cameron Facilities provides fire safety compliance inspections Perth commercial buildings, strata complexes and mining camps need to meet their statutory obligations under the Building Code of Australia and AS 1851. Regular inspection and testing of essential fire safety measures keeps building owners and managers compliant and protects occupants, not just a certificate on file.

What’s Included in Our Fire Safety Compliance Service
- AS 1851 scheduled inspection and testing of fire systems, dry and wet
- Fire extinguisher, hose reel and fire blanket servicing
- Fire door and penetration inspections
- Smoke detector and fire alarm panel testing
- Sprinkler and hydrant system testing
- Essential safety measures documentation and record keeping
- Defect identification and coordination of repairs

Fire Safety Compliance in Western Australia
An ongoing duty
In Western Australia, building owners have an ongoing duty under the Building Regulations to maintain the essential safety measures listed in a building’s fire and life safety approval, not just pass an initial inspection when the building is built.
Set service intervals
AS 1851 sets the routine service intervals for fire protection equipment, from six monthly extinguisher servicing, with routine visual checks between services, through to annual fire door and sprinkler testing, and missed or undocumented inspections are one of the most common defects raised in strata building audits.
Penetrations flagged
Because fire door integrity depends on penetrations being properly fire stopped, we flag any unsealed service penetrations found during inspection so they can be rectified alongside routine servicing, rather than waiting for the next major audit.
Why Perth Businesses Choose Cameron Facilities for Fire Safety Compliance
Fire safety compliance inspections are delivered under our ISO 9001:2015 quality management system and ISO 45001:2018 safety management system. Because fire safety forms part of our broader building management services in Perth, it can be scheduled alongside electrical maintenance, access control and security systems maintenance and building compliance inspections under a single contract. Inspection records and defect reports are tracked through our SiteIQ platform.
One contract, one record
- Fire safety scheduled with electrical, access control and compliance inspections
- Inspection records and defect reports tracked in SiteIQ
- Delivered under ISO 9001:2015 and ISO 45001:2018 systems
Fire Safety Compliance for Strata Schemes
In a strata scheme, responsibility for fire safety is split in a way that causes things to be missed. The strata company is responsible for the common property, and individual owners are responsible for what sits inside their lot. Smoke alarms, fire doors to lots and the contents of a lot fall on one side of that line, while the alarm panel, hydrants, sprinklers, extinguishers, emergency lighting and exit signs in common areas fall on the other.
Two practical consequences follow. Items on the boundary get left because each side assumes the other holds them. And the scheme's own compliance record often covers only what a contractor happened to attend, rather than everything the building has.
For a strata scheme we work from an asset register of the fire equipment the building actually holds, schedule the servicing against it, and give the council a single record it can produce on request. Where a defect is found we report it with the responsibility identified, so the council knows whether it is acting or notifying an owner.
Fire safety work is also the clearest example of why a ten year plan and a reserve fund need reconciling. Alarm panels, pumps and hydrant systems reach end of life on a schedule that is knowable years out. See our Reserve Fund Health Check and strata building management.
Laws and standards this service works within
- WA ActBuilding Act 2011 (WA)(opens in a new tab)
The WA framework for building permits, approvals and building standards.
- WA RegulationsBuilding Regulations 2012 (WA)(opens in a new tab)
Detailed WA building requirements made under the Building Act, including those that apply to existing buildings.
- StandardAS 1851-2012 Routine service of fire protection systems and equipment(opens in a new tab)
Inspection, testing and servicing intervals for fire protection systems and equipment, with records of each service.
- StandardAS/NZS 2293.2:2019 Emergency lighting and exit signs for buildings, Part 2: Routine service and maintenance(opens in a new tab)
Routine testing and maintenance of emergency lighting and exit signs so they are ready to operate.
- WA ActFire and Emergency Services Act 1998 (WA)(opens in a new tab)
Fire and emergency services powers in WA, including fire prevention obligations.
- WA ActStrata Titles Act 1985 (WA)(opens in a new tab)
Sets out how strata companies manage, maintain and repair common property.
- WA ActWork Health and Safety Act 2020 (WA)(opens in a new tab)
The main WA safety law. Sets the duties every business and contractor holds to keep workers and others safe.
Links open the official legislation, regulator or standards page. These references describe the framework this service works within. They help owners, operators and managers meet their own obligations; they do not replace them or legal advice.
Certified to ISO 9001, ISO 14001 and ISO 45001 for the provision of integrated facility management services, including cleaning, maintenance and building administration; village accommodation and mining camp management; asset register and building compliance management; and project delivery services. Members of the Strata Community Association (WA) and the Facility Management Association of Australia.
Request a Fire Safety Compliance Quote
If your building needs a scheduled fire safety compliance programme or a one off inspection, talk to Cameron Facilities. Request a quote or call (08) 6154 0910.